Document Type : Original Research Article

Authors

1 Department of Engineering, Sari Branch, Islamic Azad University, Sari, Iran

2 Neka Power Generation Management Company

Abstract

Considering the effects of DGs on the new power system, their importance has increased in the future smart grid. The number of DG units installed on the power system is growing significantly and the technical, economical and environmental effects of them on the power system are being analyzed. Currently, considerable technical effects include voltage profile, power loss, quality, reliability, protection, control and stability. The most important factors which affect the technical and the environmental issues include the type, the size and the location where the DG units are installed on the power system. The location and the size of the DG unit should be optimized in order to maximize the advantages and reduce the effects of them on the power system. In some conditions, inappropriate placement can reduce the advantage and even jeopardize the general performance of the system, so finding an optimal location and size of DG units encouraged most of the researchers to investigate this area. So far most of the researches use the DGs with unity power factor in distribution systems that have stable power loads. In this paper, an attempt was made to investigate the installation location of the multiple distributed generators influenced by the changes of the load levels. In this part, we selected a suitable location to install AND investigated the results considering the load models in order to reduce the power loss of the transmission lines, reduce the voltage deviation index and reduce the cost of DG exploitation through optimize genetic algorithm.

Graphical Abstract

Minimize Power Losses and Voltage Stability by Optimizing the Installation Location of Generators in Distributed Generation

Keywords

Main Subjects

[1] Ackermann T, Andersson G, Söder L. Electric power systems research, 2001, 57,195-204.
[2] Ghosh S, Ghosal SP, Ghosh S. Electr. Power Energy Syst., 2010, 32, 849–856.
[3] Singh RK, Gowsami SK. Electr. Power Energy Syst., 2010, 32, 637–644.
[4] Phillipson L, Willis HL. Marcell Decker Inc., New York, 1999.
[5] Moradi MH, Abedini M. Electr. Power Energy Syst., 2012, 34, 66–74.
[6] El-Zonkoly AM. Swarm Evol. Comput., 2011, 1, 50–59.
[7] Lawrence R, Middlekauff S, IEEE Industry Applications Magazine., 2005, 11 (1), 54-59.
[8] Imran M, Kowsalya A, Swarm M. Evolutionary Computation, 2013, 15, pp.58-65.
[9] Singh D, Misra RK, Singh D. IEEE Trans. Power Syst., 2007, 22 (4), 2204–2212.
[10] Jen-Hao T, IEEE Trans. Power Deliv., 2003, 18(3), 882–887.
[11] Singh D, Singh D, Verma KS. IEEE Trans. Power Syst., 2009, 24(1), 427–436.
[12] IEEE task force on load representation for dynamic performance, Load representation for dynamic Q6 performance analysis, IEEE Trans. Power Syst. 1993, 8 (2) 472–482.
[13] Sahoo NC, Prasad K. Energy Convers. Manage., 2006, 47, 3288–3306.